  1. In an electrical installation, PROMOTELEC Label requires:

    A 8 lamps per circuit and 5 sockets per circuit

    B 5 lamps per circuit and 8 sockets per circuit

    C 5 lamps per circuit and 5 sockets per circuit

    D 8 lamps per circuit and 8 sockets per circuit

  2. Figure 1

    Figure 1 represents:

    A A switch

    B A Residual Current Switch

    C An isolator

    D An isolator switch

  3. The life span of an incandescence lamp is estimated to around:

    A 2000 hours of functioning

    B 1000 hours of functioning

    C 4000 hours of functioning

    D 6000 hours of functioning

  4. If a hydroelectric power generation used a Francis turbine; hence the height of water fall,

    A Less than 30 meters

    B Greater than 200 meters

    C Less than 200 meters

    D Between 30 meters and 200 meters

  5. Figure 2

    Figure 2 represents

    A The symbol of a coil

    B The symbol of a tele-switch

    C The symbol of a timer

    D The symbol of a time-switch

  6. Figure 3

    What does the symbol in figure 3 represent?

    A A Residual Current switch

    B A switch

    C A Residual Current Circuit-breaker

    D An isolator

  7. In Cameroon, low voltage used for distribution of electrical energy is:

    A 220V/380V – 50Hz

    B 380V/660V – 50Hz

    C 230V/400V – 50Hz

    D 400V/690V – 50Hz

  8. The starting current of a three phase induction motor using direct on line starting is between:

    A 3In to 4In

    B 2.5In to 8In

    C 4In to 8In

    D 2.5In to 4In

  9. Buchholz relay used in power transformers ensures:

    A Protection against low voltage

    B Protection against internal faults

    C Protection against overcurrent

    D Protection against over leakage current

  10. In an electric conduit, the maximum volume to be occupied by conductors should be:

    A One-third

    B Half

    C One-quarter

    D Three-quarter

  11. The protection of persons against direct contact in electrical installation is ensured by

    A High sensitivity

    B Medium sensitivity

    C Residual current

    D Residual current device