cameroon gce advanced level water supply and drainage networks processes 3
cameroon gce advanced level water supply and drainage networks processes 3
I- PRESENTATION :
For the installation of a kitchen, you are requested to install a kitchen sink as indicated on the execution plan of page 3.
– The cold water distribution network is in PVC pressure pipe of nominal diameter 25mm. The supply pipe
starts from the riser coming from the lower floors.
– The domestic hot water distribution network is in Alu- plastic compression pipe of ϕ 16mm. The hot
water pipe starts from an electric hot water pipe which is located at the lower floor levels.
I- TECHNICAL SPECIFICATIONS :
Label | Designation | Label | Designation |
1 | PVC drainage pipe of ϕ 63 | 7 | 90° bend on PVC pressure pipe 25 and Alu plastics compression of ϕ 16 |
2 | PVC offset Tee 45° branch + PVC1/8 elbow of ϕ 63+ PVC reduction 63/40 |
8 | PVC pressure pipe of ϕ 25 |
3 | PVC drainage pipe 40 | 9 | Cross over on PVC pressure pipe of ϕ 25 |
4 | PVC offset Tee 45° branch + PVC 1/8 elbow of ϕ 40 + PVC reduction of ϕ 63/32 |
10 | Socket on PVC drainage pipes of ϕ 63 and ϕ 40 |
5 | Alu- plastic compression pipe of ϕ 16 | 11 | Cross over on PVC pressure pipe of ϕ 25 and Alu-plastics in compression pipe of ϕ 16 |
6 | Brass compression Tee fitting 16 |