I- PRESENTATION :
For the installation of a kitchen, you are requested to install a kitchen sink as indicated on the execution plan of page 3.
– The cold water distribution network is in PVC pressure pipe of nominal diameter 25mm. The supply pipe
starts from the riser coming from the lower floors.
– The domestic hot water distribution network is in Alu- plastic compression pipe of ϕ 16mm. The hot
water pipe starts from an electric hot water pipe which is located at the lower floor levels.
I- TECHNICAL SPECIFICATIONS :

Label Designation Label Designation
1 PVC drainage pipe of ϕ 63 7 90° bend on PVC pressure pipe 25 and Alu
plastics compression of ϕ 16
2 PVC offset Tee 45° branch + PVC1/8 elbow
of ϕ 63+ PVC reduction 63/40
8 PVC pressure pipe of ϕ 25
3 PVC drainage pipe 40 9 Cross over on PVC pressure pipe of ϕ 25
4 PVC offset Tee 45° branch + PVC 1/8 elbow
of ϕ 40 + PVC reduction of ϕ 63/32
10 Socket on PVC drainage pipes of ϕ 63 and ϕ 40
5 Alu- plastic compression pipe of ϕ 16 11 Cross over on PVC pressure pipe of ϕ 25 and
Alu-plastics in compression pipe of ϕ 16
6 Brass compression Tee fitting 16